Acoustical

Acoustical

Acoustical louvers are designed to reduce noise transmission while protecting air intake and exhaust openings. These non-drainable models feature airfoil blades filled with sound-absorbing insulation to attenuate noise from heavy equipment and mechanical systems. Available in a range of frame depths, blade angles, and spacings, they are constructed from aluminum or steel to meet both acoustic and architectural requirements.

 

Model Description Orientation
H – Horz, V – Vert
Angle Deg. Spacing Inches Depth Inches Sq. Ft. % Water Penetration Rating (WPR)
Feet/minute
Pressure Drop @ WPR
inches W.C.
Air Flow SCFM Material Thickness
(Frame/Blade/Perf) Inches
AMCA STC Class Min W x H Inches Max W x H Inches
LAA-66 Fixed Non-drainable H 45.0 6.00 6.00 6.43 26 898* 0.08 3649 0.080 / 0.063 / 0.092 Y 12 12 x 12 72 x 96
LAA-86 Fixed Non-drainable H 45.0 6.00 8.00 6.76 27 950* 0.10 4498 0.080 / 0.063 / 0.092 Y 14 12 x 12 72 x 96
LAA-88 Fixed Non-drainable H 45.0 8.00 8.00 7.08 28 926 0.09 3834 0.080 / 0.063 / 0.092 Y 13 12 x 12 72 x 96
LAA-129 Fixed Non-drainable H 45.0 10.00 8.00 7.94 31 930* 0.13 3955 0.080 / 0.063 / 0.092 14 12 x 12 72 x 96
LAA-1212 Fixed Non-drainable H 45.0 12.00 12.00 6.32 25 1089 0.16 3695 0.080 / 0.063 / 0.092 13 12 x 12 72 x 96
LAA-1215 Fixed Non-drainable H 45.0 15.00 12.00 5.93 35 1173* 0.13 6487 0.080 / 0.063 / 0.092 10 12 x 36 72 x 96
LAA-12AF Fixed Non-drainable H 45.0 12.00 12.00 4.63 22 1127 0.06 4001 0.080 / 0.063 / 0.092 10 12 x 14 72 x 96

Notes:
AMCA certified performance based on 4” x 4” louver
Standard construction designed for 25 PSF (100 mph) wind load for maximum single panel size
*Pressure drop velocity only

Sound Attenuation Ratings
Model Octave Band 1 2 3 4 5 6 7 8
63 125 250 500 1000 2000 4000 8000
LAA-66 Transmission Loss (dB) 1 6 5 9 13 15 14 14
Free Field Noise Reduction (dB) 7 12 15 19 21 21 21 20
LAA-86 Transmission Loss (dB) 1 4 4 8 13 14 13 13
Free Field Noise Reduction (dB) 7 10 13 18 22 25 25 23
LAA-88 Transmission Loss (dB) 1 5 6 9 13 16 13 11
Free Field Noise Reduction (dB) 7 11 14 18 22 25 22 20
LAA-129 Transmission Loss (dB) 2 8 11 13 22 28 25 17
Free Field Noise Reduction (dB) 8 14 18 22 29 34 31 23
LAA-1212 Transmission Loss (dB) 9 7 11 14 21 25 21 17
Free Field Noise Reduction (dB) 15 13 19 25 29 30 27 22
LAA-1215 Transmission Loss (dB) 2 6 10 12 20 26 24 19
Free Field Noise Reduction (dB) 8 12 17 23 28 33 31 26
LAA-12AF Transmission Loss (dB) 7 6 7 13 19 17 16 14
Free Field Noise Reduction (dB) 14 12 14 19 21 19 16 15